Skip to main content

Table 5 Summary of the results for low power design

From: A design and implementation of low-power ultrasonic water meter

 

1st test

2nd test

3rd test

Avg.

typical

Geo. mean

max

Current consumption [μA]

21.97

20.39

20.39

20.92

6.42

17.0

45.06

Power consumption when used for 10 years [mAh]

1924.6

1780.9

1786.1

1830.5

562.4

1489.9

3947

Life span of batteries [years]

22.0

23.8

23.7

23.2

75.6

28.5

10.8