Skip to main content

Table 5 Summary of the results for low power design

From: A design and implementation of low-power ultrasonic water meter

 1st test2nd test3rd testAvg.typicalGeo. meanmax
Current consumption [μA]21.9720.3920.3920.926.4217.045.06
Power consumption when used for 10 years [mAh]1924.61780.91786.11830.5562.41489.93947
Life span of batteries [years]22.023.823.723.275.628.510.8